Thanks for the update Moron.
So it is actually 40% higher than what I referenced.
Again, thanks
The problem is that once output drops to around 70% per cell, the panel ampacity starts to rise and you run the increasing risk of a fire as voltage goes down and amperage goes up. Failed cells also increase this chance. You start looking at a serious electrical fire hazard using degraded panels.
Unrelated to the panels, I personally have seen at least a dozen badly installed home solar arrays. Typically, the company installing them shaves every corner they can and their engineers fail to consider stuff in the design that can cause serious and even dangerous problems.
They do stuff like:
Size the wire to the minimum allowable. This is a problem in Arizona where the wiring is run in metal conduit and the wire often exceeds the 75 C degree rise allowed by Code. This will result in the premature failure of the insulation and can result in grounding and shorts.
They often undersize the breaker that is installed in the home's service. I've seen two that were like that with the breaker so hot that you couldn't touch it up to 30 minutes after replacement.
Another is they do the roof penetrations wrong and your roof leaks. They put it in their contract that this might happen and it is on you to fix it.
Depending on the array installed, the roof might not structurally support the added load causing your rafters or trusses to sag and the roof to become unstable or hold water.
They will also put a solar array on an old roof without a second thought. That means when you go to re-shingle your roof you have to remove the array before that can happen and then reinstall it afterwards. That usually requires a professional and can add a thousand or more to your roofing cost.
While panel fires themselves are rare, they do happen. Usually though, it is a sloppy installation by workers and the engineer that designed your system cutting corners to save cost that's the real danger.
However, like I said, once the voltage drops to about 70% things start to not work any more. Its no different than trying to run your 120 VAC computer off 80 VAC. That doesn't work and you wipe out the computer's power supply in short order.